First, check the power supply: whether the connector is firmly connected; Whether the switch contacts tightly; Whether the fuse is blown; Whether three-phase power supply is equal. In case of open circuit, poor contact, fuse blown and phase...
2017-09-27
Cause: the packing is too tight or the impeller and pump body are blocked by sundries; Pump shaft, bearing and leakage ring rusted; The pump shaft is severely bent.
Troubleshooting: loosen the packing and dredge the water diversion tank:...
Calculation formula of shaft power of centrifugal pump
flow × lift × nine point eight one × Medium specific gravity ÷ 3600 ÷ pump efficiency
Flow unit: m3 / h,
Lift unit: M
P=2.73HQ/ η,